thermal/of: Fix cdev lookup in thermal_of_should_bind()
Since thermal_of_should_bind() terminates the loop after processing
the first child found in cooling-maps, it will never match more than
one cdev to a given trip point which is incorrect, as there may be
cooling-maps associating one trip point with multiple cooling devices.
Address this by letting the loop continue until either all
children have been processed or a matching one has been found.
To avoid adding conditionals or goto statements, put the loop in
question into a separate function and make that function return
right away after finding a matching cooling-maps entry.
Fixes: 94c6110b0b
("thermal/of: Use the .should_bind() thermal zone callback")
Link: https://lore.kernel.org/linux-pm/20250219-fix-thermal-of-v1-1-de36e7a590c4@chromium.org/
Reported-by: Yu-Che Cheng <giver@chromium.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Yu-Che Cheng <giver@chromium.org>
Tested-by: Yu-Che Cheng <giver@chromium.org>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://patch.msgid.link/2788228.mvXUDI8C0e@rjwysocki.net
This commit is contained in:
parent
4ecaa75771
commit
423de5b5bc
1 changed files with 29 additions and 21 deletions
|
@ -274,6 +274,34 @@ static bool thermal_of_get_cooling_spec(struct device_node *map_np, int index,
|
|||
return true;
|
||||
}
|
||||
|
||||
static bool thermal_of_cm_lookup(struct device_node *cm_np,
|
||||
const struct thermal_trip *trip,
|
||||
struct thermal_cooling_device *cdev,
|
||||
struct cooling_spec *c)
|
||||
{
|
||||
for_each_child_of_node_scoped(cm_np, child) {
|
||||
struct device_node *tr_np;
|
||||
int count, i;
|
||||
|
||||
tr_np = of_parse_phandle(child, "trip", 0);
|
||||
if (tr_np != trip->priv)
|
||||
continue;
|
||||
|
||||
/* The trip has been found, look up the cdev. */
|
||||
count = of_count_phandle_with_args(child, "cooling-device",
|
||||
"#cooling-cells");
|
||||
if (count <= 0)
|
||||
pr_err("Add a cooling_device property with at least one device\n");
|
||||
|
||||
for (i = 0; i < count; i++) {
|
||||
if (thermal_of_get_cooling_spec(child, i, cdev, c))
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
return false;
|
||||
}
|
||||
|
||||
static bool thermal_of_should_bind(struct thermal_zone_device *tz,
|
||||
const struct thermal_trip *trip,
|
||||
struct thermal_cooling_device *cdev,
|
||||
|
@ -293,27 +321,7 @@ static bool thermal_of_should_bind(struct thermal_zone_device *tz,
|
|||
goto out;
|
||||
|
||||
/* Look up the trip and the cdev in the cooling maps. */
|
||||
for_each_child_of_node_scoped(cm_np, child) {
|
||||
struct device_node *tr_np;
|
||||
int count, i;
|
||||
|
||||
tr_np = of_parse_phandle(child, "trip", 0);
|
||||
if (tr_np != trip->priv)
|
||||
continue;
|
||||
|
||||
/* The trip has been found, look up the cdev. */
|
||||
count = of_count_phandle_with_args(child, "cooling-device", "#cooling-cells");
|
||||
if (count <= 0)
|
||||
pr_err("Add a cooling_device property with at least one device\n");
|
||||
|
||||
for (i = 0; i < count; i++) {
|
||||
result = thermal_of_get_cooling_spec(child, i, cdev, c);
|
||||
if (result)
|
||||
break;
|
||||
}
|
||||
|
||||
break;
|
||||
}
|
||||
result = thermal_of_cm_lookup(cm_np, trip, cdev, c);
|
||||
|
||||
of_node_put(cm_np);
|
||||
out:
|
||||
|
|
Loading…
Add table
Reference in a new issue