Add definition for VXLAN and Geneve dummy packet. Define VXLAN and
Geneve type of fields to match on correct UDP tunnel header.
Parse tunnel specific fields from TC tool like outer MACs, outer IPs,
outer destination port and VNI. Save values and masks in outer header
struct and move header pointer to inner to simplify parsing inner
values.
There are two cases for redirect action:
- from uplink to VF - TC filter is added on tunnel device
- from VF to uplink - TC filter is added on PR, for this case check if
redirect device is tunnel device
VXLAN example:
- create tunnel device
ip l add $VXLAN_DEV type vxlan id $VXLAN_VNI dstport $VXLAN_PORT \
dev $PF
- add TC filter (in switchdev mode)
tc filter add dev $VXLAN_DEV protocol ip parent ffff: flower \
enc_dst_ip $VF1_IP enc_key_id $VXLAN_VNI action mirred egress \
redirect dev $VF1_PR
Geneve example:
- create tunnel device
ip l add $GENEVE_DEV type geneve id $GENEVE_VNI dstport $GENEVE_PORT \
remote $GENEVE_IP
- add TC filter (in switchdev mode)
tc filter add dev $GENEVE_DEV protocol ip parent ffff: flower \
enc_key_id $GENEVE_VNI dst_ip $GENEVE1_IP action mirred egress \
redirect dev $VF1_PR
Signed-off-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com>
Tested-by: Sandeep Penigalapati <sandeep.penigalapati@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
Implement indirect notification mechanism to support offloading TC rules
on tunnel devices.
Keep indirect block list in netdev priv. Notification will call setting
tc cls flower function. For now we can offload only ingress type. Return
not supported for other flow block binder.
Signed-off-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com>
Acked-by: Paul Menzel <pmenzel@molgen.mpg.de>
Tested-by: Sandeep Penigalapati <sandeep.penigalapati@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
Add support to add/delete channel specific filter using tc-flower.
For now, only supported action is "skip_sw hw_tc <tc_num>"
Filter criteria is specific to channel and it can be
combination of L3, L3+L4, L2+L4.
Example:
MATCH criteria Action
---------------------------
src and/or dest IPv4[6]/mask -> Forward to "hw_tc <tc_num>"
dest IPv4[6]/mask + dest L4 port -> Forward to "hw_tc <tc_num>"
dest MAC + dest L4 port -> Forward to "hw_tc <tc_num>"
src IPv4[6]/mask + src L4 port -> Forward to "hw_tc <tc_num>"
src MAC + src L4 port -> Forward to "hw_tc <tc_num>"
Adding tc-flower filter for channel using "hw_tc"
-------------------------------------------------
tc qdisc add dev <ethX> clsact
Above two steps are only needed the first time when adding
tc-flower filter.
tc filter add dev <ethX> protocol ip ingress prio 1 flower \
dst_ip 192.168.0.1/32 ip_proto tcp dst_port 5001 \
skip_sw hw_tc 1
tc filter show dev <ethX> ingress
filter protocol ip pref 1 flower chain 0
filter protocol ip pref 1 flower chain 0 handle 0x1 hw_tc 1
eth_type ipv4
ip_proto tcp
dst_ip 192.168.0.1
dst_port 5001
skip_sw
in_hw in_hw_count 1
Delete specific filter:
-------------------------
tc filter del dev <ethx> ingress pref 1 handle 0x1 flower
Delete All filters:
------------------
tc filter del dev <ethX> ingress
Co-developed-by: Amritha Nambiar <amritha.nambiar@intel.com>
Signed-off-by: Amritha Nambiar <amritha.nambiar@intel.com>
Signed-off-by: Kiran Patil <kiran.patil@intel.com>
Signed-off-by: Sudheer Mogilappagari <sudheer.mogilappagari@intel.com>
Tested-by: Bharathi Sreenivas <bharathi.sreenivas@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
Add tc-flower support for VF port representor devices.
Implement ndo_setup_tc callback for TC HW offload on VF port representors
devices. Implemented both methods: add and delete tc-flower flows.
Mark NETIF_F_HW_TC bit in net device's feature set to enable offload TC
infrastructure for port representor.
Implement TC filters replay function required to restore filters settings
while switchdev configuration is rebuilt.
Signed-off-by: Michal Swiatkowski <michal.swiatkowski@intel.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sandeep Penigalapati <sandeep.penigalapati@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
Implement ndo_setup_tc net device callback for TC HW offload on PF device.
ndo_setup_tc provides support for HW offloading various TC filters.
Add support for configuring the following filter with tc-flower:
- default L2 filters (src/dst mac addresses, ethertype, VLAN)
- variations of L3, L3+L4, L2+L3+L4 filters using advanced filters
(including ipv4 and ipv6 addresses).
Allow for adding/removing TC flows when PF device is configured in
eswitch switchdev mode. Two types of actions are supported at the
moment: FLOW_ACTION_DROP and FLOW_ACTION_REDIRECT.
Co-developed-by: Priyalee Kushwaha <priyalee.kushwaha@intel.com>
Signed-off-by: Priyalee Kushwaha <priyalee.kushwaha@intel.com>
Signed-off-by: Kiran Patil <kiran.patil@intel.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sandeep Penigalapati <sandeep.penigalapati@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>