Add support for probing MMDs above 7 for a valid devices-in-package
specifier, but only probe the vendor MMDs for this if they also report
that there the device is present in status register 2. This avoids
issues where the MMD is implemented, but does not provide IEEE 802.3
compliant registers (such as the MV88X3310 PHY.)
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Reword the get_phy_device() kerneldoc to be more explicit about how
we probe for the PHY, and what the various return conditions signify.
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Move the ID check from get_phy_device() into get_phy_c22_id(), which
simplifies get_phy_device(). The ID reading functions are now
responsible for indicating whether they found a PHY or not via their
return code - they must return -ENODEV when a PHY is not present.
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
When we decide that a PHY is not present, we do not need to go through
the hoops of setting *phy_id to 0xffffffff, and then return zero to
make get_phy_device() fail - we can return -ENODEV which will have the
same effect.
Doing so means we no longer have to pass a pointer to phy_id in, and
we can then clean up the clause 22 path in a similar way.
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Rearrange the code to read the PHY IDs, so we don't call get_phy_id()
only to immediately call get_phy_c45_ids(). Move that logic into
get_phy_device(), which results in better readability.
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Move the Cortina PHY workaround out of the "devices in package" loop;
it doesn't need to be in there as the control flow will terminate the
loop once we enter the workaround irrespective of the workaround's
outcome. The workaround is triggered by the ID being mostly 1's, which
will in any case terminate the loop.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Commit 02a6efcab6 ("net: phy: allow scanning busses with missing
phys") added a special condition to return -ENODEV in case -ENODEV or
-EIO was returned from the first read of the MII_PHYSID1 register.
In case the MDIO bus data line pull-up is not strong enough, the MDIO
bus controller will not flag this as a read error. This can happen when
a pluggable daughter card is not connected and weak internal pull-ups
are used (since that is the only option, otherwise the pins are
floating).
The second read of MII_PHYSID2 will be correctly flagged an error
though, but now we will return -EIO which will be treated as a hard
error, thus preventing MDIO bus scanning loops to continue succesfully.
Apply the same logic to both register reads, thus allowing the scanning
logic to proceed.
Fixes: 02a6efcab6 ("net: phy: allow scanning busses with missing phys")
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
There is a recurring pattern throughout some of the PHY code converting
a devad and regnum to our packed clause 45 representation. Rather than
having this scattered around the code, let's put a common translation
function in mdio.h, and provide some register accessors.
Convert the phylib core, phylink, bcm87xx and cortina to use these.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The MSCC bug fix in 'net' had to be slightly adjusted because the
register accesses are done slightly differently in net-next.
Signed-off-by: David S. Miller <davem@davemloft.net>
This function was introduced to allow for different handling of
link up and link down events particularly with regard to the
netif_carrier. The third argument do_carrier allowed the flag to
be left unchanged.
Since then the phylink has introduced an implementation that
completely ignores the third parameter since it never wants to
change the flag and the phylib always sets the third parameter
to true so the flag is always changed.
Therefore the third argument (i.e. do_carrier) is no longer
necessary and can be removed. This also means that the phylib
phy_link_down() function no longer needs its second argument.
Signed-off-by: Doug Berger <opendmb@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The compilation warning below reveals that the errors returned from
the sfp_bus_add_upstream() call are not propagated to the callers.
Fix it by returning "ret".
14:37:51 drivers/net/phy/phy_device.c: In function 'phy_sfp_probe':
14:37:51 drivers/net/phy/phy_device.c:1236:6: warning: variable 'ret'
set but not used [-Wunused-but-set-variable]
14:37:51 1236 | int ret;
14:37:51 | ^~~
Fixes: 298e54fa81 ("net: phy: add core phylib sfp support")
Signed-off-by: Leon Romanovsky <leonro@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The unsigned variable val is being checked for an error by checking
if it is less than zero. This can never occur because val is unsigned.
Fix this by making val a plain int.
Addresses-Coverity: ("Unsigned compared against zero")
Fixes: bdbdac7649 ("ethtool: provide UAPI for PHY master/slave configuration.")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This UAPI is needed for BroadR-Reach 100BASE-T1 devices. Due to lack of
auto-negotiation support, we needed to be able to configure the
MASTER-SLAVE role of the port manually or from an application in user
space.
The same UAPI can be used for 1000BASE-T or MultiGBASE-T devices to
force MASTER or SLAVE role. See IEEE 802.3-2018:
22.2.4.3.7 MASTER-SLAVE control register (Register 9)
22.2.4.3.8 MASTER-SLAVE status register (Register 10)
40.5.2 MASTER-SLAVE configuration resolution
45.2.1.185.1 MASTER-SLAVE config value (1.2100.14)
45.2.7.10 MultiGBASE-T AN control 1 register (Register 7.32)
The MASTER-SLAVE role affects the clock configuration:
-------------------------------------------------------------------------------
When the PHY is configured as MASTER, the PMA Transmit function shall
source TX_TCLK from a local clock source. When configured as SLAVE, the
PMA Transmit function shall source TX_TCLK from the clock recovered from
data stream provided by MASTER.
iMX6Q KSZ9031 XXX
------\ /-----------\ /------------\
| | | | |
MAC |<----RGMII----->| PHY Slave |<------>| PHY Master |
|<--- 125 MHz ---+-<------/ | | \ |
------/ \-----------/ \------------/
^
\-TX_TCLK
-------------------------------------------------------------------------------
Since some clock or link related issues are only reproducible in a
specific MASTER-SLAVE-role, MAC and PHY configuration, it is beneficial
to provide generic (not 100BASE-T1 specific) interface to the user space
for configuration flexibility and trouble shooting.
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are packages which contain multiple PHY devices, eg. a quad PHY
transceiver. Provide functions to allocate and free shared storage.
Usually, a quad PHY contains global registers, which don't belong to any
PHY. Provide convenience functions to access these registers.
Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If a soft reset is triggered whilst PHY is in power-down, then
phydev->suspended will remain set. Seems we didn't face any issue yet
caused by this, but better reset the suspended flag after soft reset.
See also the following from 22.2.4.1.1
Resetting a PHY is accomplished by setting bit 0.15 to a logic one.
This action shall set the status and control registers to their default
states.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Since 6e2d85ec05 ("net: phy: Stop with excessive soft reset")
we don't need genphy_no_soft_reset() any longer. Not setting
callback soft_reset results in a no-op now.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Gently handle the case that phy_suspend() is called whilst PHY is in
power-down.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
So far we set phydev->suspended to true in phy_suspend() even if the
PHY driver doesn't implement the suspend callback. This applies
accordingly for the resume path. The current behavior doesn't cause
any issue I'd be aware of, but it's not logical and misleading,
especially considering the description of the flag:
"suspended: Set to true if this phy has been suspended successfully"
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If we have scenarios like
mdiobus_register()
-> loads PHY driver module(s)
-> registers PHY driver(s)
-> may schedule async probe
phydev = mdiobus_get_phy()
<phydev action involving PHY driver>
or
phydev = phy_device_create()
-> loads PHY driver module
-> registers PHY driver
-> may schedule async probe
<phydev action involving PHY driver>
then we expect the PHY driver to be bound to the phydev when triggering
the action. This may not be the case in case of asynchronous probing.
Therefore ensure that PHY drivers are probed synchronously.
Default still is sync probing, except async probing is explicitly
requested. I saw some comments that the intention is to promote
async probing for more parallelism in boot process and want to be
prepared for the case that the default is changed to async probing.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
use phy_read_poll_timeout() to replace the poll codes for
simplify the code in phy_poll_reset() function.
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Dejin Zheng <zhengdejin5@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
So far we have the unfortunate situation that mdio_bus_phy_may_suspend()
is called in suspend AND resume path, assuming that function result is
the same. After the original change this is no longer the case,
resulting in broken resume as reported by Geert.
To fix this call mdio_bus_phy_may_suspend() in the suspend path only,
and let the phy_device store the info whether it was suspended by
MDIO bus PM.
Fixes: 503ba7c696 ("net: phy: Avoid multiple suspends")
Reported-by: Geert Uytterhoeven <geert@linux-m68k.org>
Tested-by: Geert Uytterhoeven <geert@linux-m68k.org>
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The mptcp conflict was overlapping additions.
The SMC conflict was an additional and removal happening at the same
time.
Signed-off-by: David S. Miller <davem@davemloft.net>
When auto-negotiation is not required, return value should be zero.
Changes v1->v2:
- improved comments and code as Andrew Lunn and Heiner Kallweit suggestion
- fixed issue in genphy_c45_check_and_restart_aneg as Russell King
suggestion.
Fixes: 2a10ab043a ("net: phy: add genphy_check_and_restart_aneg()")
Fixes: 1af9f16840 ("net: phy: add genphy_c45_check_and_restart_aneg()")
Signed-off-by: Sudheesh Mavila <sudheesh.mavila@amd.com>
Reviewed-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
It is currently possible for a PHY device to be suspended as part of a
network device driver's suspend call while it is still being attached to
that net_device, either via phy_suspend() or implicitly via phy_stop().
Later on, when the MDIO bus controller get suspended, we would attempt
to suspend again the PHY because it is still attached to a network
device.
This is both a waste of time and creates an opportunity for improper
clock/power management bugs to creep in.
Fixes: 803dd9c77a ("net: phy: avoid suspending twice a PHY")
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
commit 93c0970493 ("net: phy: consider latched link-down status in
polling mode") removed double-read of latched link-state register for
polling mode from genphy_update_link(). This added extra ~1s delay into
sequence link down->up.
Following scenario:
- After boot link goes up
- phy_start() is called triggering an aneg restart, hence link goes
down and link-down info is latched.
- After aneg has finished link goes up. In phy_state_machine is checked
link state but it is latched "link is down". The state machine is
scheduled after one second and there is detected "link is up". This
extra delay can be avoided when we keep link-state register double read
in case when link was down previously.
With this solution we don't miss a link-down event in polling mode and
link-up is faster.
Details about this quirky behavior on Realtek phy:
Without patch:
T0: aneg is started, link goes down, link-down status is latched
T0+3s: state machine runs, up-to-date link-down is read
T0+4s: state machine runs, aneg is finished (BMSR_ANEGCOMPLETE==1),
here i read link-down (BMSR_LSTATUS==0),
T0+5s: state machine runs, aneg is finished (BMSR_ANEGCOMPLETE==1),
up-to-date link-up is read (BMSR_LSTATUS==1),
phydev->link goes up, state change PHY_NOLINK to PHY_RUNNING
With patch:
T0: aneg is started, link goes down, link-down status is latched
T0+3s: state machine runs, up-to-date link-down is read
T0+4s: state machine runs, aneg is finished (BMSR_ANEGCOMPLETE==1),
first BMSR read: BMSR_ANEGCOMPLETE==1 and BMSR_LSTATUS==0,
second BMSR read: BMSR_ANEGCOMPLETE==1 and BMSR_LSTATUS==1,
phydev->link goes up, state change PHY_NOLINK to PHY_RUNNING
Signed-off-by: Petr Oros <poros@redhat.com>
Reviewed-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add a linkmode helper to set the flow control advertisement in an
ethtool linkmode mask according to the tx/rx capabilities. This
implementation is moved from phylib, and documented with an
analysis of its shortcomings.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add a couple of helpers to resolve negotiated flow control. Two helpers
are provided:
- linkmode_resolve_pause() which takes the link partner and local
advertisements, and decodes whether we should enable TX or RX pause
at the MAC. This is useful outside of phylib, e.g. in phylink.
- phy_get_pause(), which returns the TX/RX enablement status for the
current negotiation results of the PHY.
This allows us to centralise the flow control resolution, rather than
spreading it around.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
The information about the PHY attached to the PHYLINK instance is useful
but is missing the IRQ prints that phy_attached_info() adds.
phy_attached_info() is a bit long and it would not be possible to use
phylink_info() anyway.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When parsing a PHY node, register its time stamper, if any, and attach
the instance to the PHY device.
Signed-off-by: Richard Cochran <richardcochran@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Currently the stack supports time stamping in PHY devices. However,
there are newer, non-PHY devices that can snoop an MII bus and provide
time stamps. In order to support such devices, this patch introduces
a new interface to be used by both PHY and non-PHY devices.
In addition, the one and only user of the old PHY time stamping API is
converted to the new interface.
Signed-off-by: Richard Cochran <richardcochran@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
PHY IDs are 32-bit unsigned quantities. Ensure that they are always
treated as such, and not passed around as "int"s.
Fixes: 13d0ab6750 ("net: phy: check return code when requesting PHY driver module")
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
There are two drivers and generic code which contain exactly the same
code to read the status of a PHY operating without autonegotiation
enabled. Rather than duplicate this code, provide a helper to read
this information.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add a helper for restarting autonegotiation(), similar to the clause 45
variant. Use it in __genphy_config_aneg()
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Remove initialisers that set .aneg_done to genphy_aneg_done - this is
the default for clause 22 PHYs, so the initialiser is redundant.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a phydev is created, the speed and duplex are set to zero and
-1 respectively, rather than using the predefined SPEED_UNKNOWN and
DUPLEX_UNKNOWN constants.
There is a window at initialisation time where we may report link
down using the 0/-1 values. Tidy this up and use the predefined
constants, so debug doesn't complain with:
"Unsupported (update phy-core.c)/Unsupported (update phy-core.c)"
when the speed and duplex settings are printed.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
We currently match clause 45 PHYs using any ID read from a MMD marked
as present in the "Devices in package" registers 5 and 6. However,
this is incorrect. 45.2 says:
"The definition of the term package is vendor specific and could be
a chip, module, or other similar entity."
so a package could be more or less than the whole PHY - a PHY could be
made up of several modules instantiated onto a single chip such as the
Marvell 88x3310, or some of the MMDs could be disabled according to
chip configuration, such as the Broadcom 84881.
In the case of Broadcom 84881, the "Devices in package" registers
contain 0xc000009b, meaning that there is a PHYXS present in the
package, but all registers in MMD 4 return 0xffff. This leads to our
matching code incorrectly binding this PHY to one of our generic PHY
drivers.
This patch changes the way we determine whether to attempt to match a
MMD identifier, or use it to request a module - if the identifier is
all-ones, then we skip over it. When reading the identifiers, we
initialise phydev->c45_ids.device_ids to all-ones, only reading the
device ID if the "Devices in package" registers indicates we should.
This avoids the generic drivers incorrectly matching on a PHY ID of
0xffffffff.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add core phylib help for supporting SFP sockets on PHYs. This provides
a mechanism to inform the SFP layer about PHY up/down events, and also
unregister the SFP bus when the PHY is going away.
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds support for clause 37 1000Base-X auto-negotiation.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: Tao Ren <taoren@fb.com>
Tested-by: René van Dorst <opensource@vdorst.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
Modify the assignment to OR when dealing with phydev->dev_flags in
phy_attach_direct function, and this is to make sure dev_flags set in
driver's probe callback won't be lost.
Suggested-by: Andrew Lunn <andrew@lunn.ch>
CC: Heiner Kallweit <hkallweit1@gmail.com>
CC: Vladimir Oltean <olteanv@gmail.com>
Signed-off-by: Tao Ren <taoren@fb.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Some drivers just call phy_ethtool_ksettings_set() to set the
links, for those phy drivers that use genphy_read_status(), if
autoneg is on, and the link is up, than execute "ethtool -s
ethx autoneg on" will cause "link partner" information disappear.
The call trace is phy_ethtool_ksettings_set()->phy_start_aneg()
->linkmode_zero(phydev->lp_advertising)->genphy_read_status(),
the link didn't change, so genphy_read_status() just return, and
phydev->lp_advertising is zero now.
This patch moves the clear operation of lp_advertising from
phy_start_aneg() to genphy_read_lpa()/genphy_c45_read_lpa(), and
if autoneg on and autoneg not complete, just clear what the
generic functions care about.
Fixes: 88d6272aca ("net: phy: avoid unneeded MDIO reads in genphy_read_status")
Signed-off-by: Yonglong Liu <liuyonglong@huawei.com>
Reviewed-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Move reading the link partner advertisement out of genphy_read_status()
into its own separate function. This will allow re-use of this code by
PHY drivers that are able to read the resolved status from the PHY.
Tested-by: tinywrkb <tinywrkb@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
Now that all users have been removed we can remove genphy_config_init.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Value of MII_CTRL1000 is needed only if LPA_1000MSFAIL is set.
Therefore move reading this register.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
After configuring and restarting aneg we immediately try to read the
link status. On some systems the PHY may not yet have cleared the
"aneg complete" and "link up" bits, resulting in a false link-up
signal. See [0] for a report.
Clause 22 and 45 both require the PHY to keep the AN_RESTART
bit set until the PHY actually starts auto-negotiation.
Let's consider this in the generic functions for reading link status.
The commit marked as fixed is the first one where the patch applies
cleanly.
[0] https://marc.info/?t=156518400300003&r=1&w=2
Fixes: c1164bb1a6 ("net: phy: check PMAPMD link status only in genphy_c45_read_link")
Tested-by: Yonglong Liu <liuyonglong@huawei.com>
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
The integrated PHY in 2.5Gbps chip RTL8125 is the first (known to me)
PHY that uses standard Clause 22 for all modes up to 1Gbps and adds
2.5Gbps control using vendor-specific registers. To use phylib for
the standard part little extensions are needed:
- Move most of genphy_config_aneg to a new function
__genphy_config_aneg that takes a parameter whether restarting
auto-negotiation is needed (depending on whether content of
vendor-specific advertisement register changed).
- Don't clear phydev->lp_advertising in genphy_read_status so that
we can set non-C22 mode flags before.
Basically both changes mimic the behavior of the equivalent Clause 45
functions.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Using linkmode_adv_to_mii_adv_t and linkmode_adv_to_mii_ctrl1000_t
allows to simplify the code. In addition avoiding the conversion to
the legacy u32 advertisement format allows to remove the warning.
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Suggested-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
In phy_start_aneg() autoneg is started, and immediately after that
link and autoneg status are read. As reported in [0] it can happen that
at time of this read the PHY has reset the "aneg complete" bit but not
yet the "link up" bit, what can result in a false link-up detection.
To fix this don't report link as up if we're in aneg mode and PHY
doesn't signal "aneg complete".
[0] https://marc.info/?t=156413509900003&r=1&w=2
Fixes: 4950c2ba49 ("net: phy: fix autoneg mismatch case in genphy_read_status")
Reported-by: liuyonglong <liuyonglong@huawei.com>
Tested-by: liuyonglong <liuyonglong@huawei.com>
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>